{"product_id":"lenovo-thinksystem-raid-93016i-4gb-flash-pcie-12gb-adapter","title":"LENOVO ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb адаптер","description":"\u003cdiv class=\"productName\"\u003e\n LENOVO ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter\n\u003c\/div\u003e \n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"head\"\u003e \n \u003ctbody\u003e\n  \u003ctr class=\"alt-0\"\u003e \n   \u003ctd class=\"name\"\u003e \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e \u003c\/td\u003e \n   \u003ctd class=\"image\" rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/actebis-images.com\/productimages\/eafbaaba-5b3c-46e3-8ba0-7a6dfe9ed31d.jpg\"\u003e\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eManufacturer\u003c\/td\u003e \n   \u003ctd class=\"value\"\u003eLENOVO\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eManufacturer Part No\u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e7Y37A01085\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr\u003e\n   \u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e \n \u003c\/tbody\u003e\n\u003c\/table\u003e \n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"properties\"\u003e \n \u003ctbody\u003e\n  \u003ctr class=\"sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eMarketing Description\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"marketingText\"\u003e\n   \u003ctd colspan=\"2\"\u003eThe Lenovo ThinkSystem 930-16i storage controller is engineered to meet the demands of high-performance storage systems. It features an LSI LSISAS3516 processor, providing robust data processing capabilities that are essential for managing complex RAID configurations and ensuring efficient data transfers. With support for up to 16 storage devices through its four internal 36-pin 4x Mini SAS HD (SFF-8643) connectors, it offers scalability and flexibility in storage management. This controller supports a wide range of RAID levels, including RAID 0, 1, 10, 5, 50, 6, and 60, allowing users to optimize their storage for performance, redundancy, or a balance of both. Additionally, features like CacheVault flash cache protection and SafeStore enhance data security, protecting against data loss and corruption. Designed to operate in a variety of environmental conditions, and compliant with numerous standards, the Lenovo ThinkSystem 930-16i is a reliable choice for businesses looking to maximize their storage system's efficiency and data integrity.\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"sectionHead\"\u003e \n   \u003ctd colspan=\"2\"\u003eProduct Features\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"featuresText\"\u003e \n   \u003ctd colspan=\"2\"\u003e\n    \u003cul\u003e\n     \u003cli\u003e\n\u003cstrong\u003eRobust performance\u003c\/strong\u003e\u003cbr\u003eEquipped with the LSI LSISAS3516 processor, this storage controller delivers reliable and high-speed data processing capabilities, ensuring efficient management of data transfers and RAID configurations.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eVersatile connectivity\u003c\/strong\u003e\u003cbr\u003eFeaturing four internal 36-pin 4x Mini SAS HD (SFF-8643) connectors, the Lenovo ThinkSystem 930-16i offers flexible and high-performance options for connecting up to 16 storage devices, supporting both SAS 12 Gb\/s and SATA interfaces.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eAdvanced RAID support\u003c\/strong\u003e\u003cbr\u003eWith support for multiple RAID levels, including RAID 0, 1, 10, 5, 50, 6, and 60, this storage controller provides a range of options for data protection and performance optimization, catering to diverse storage requirements.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eEnhanced data protection\u003c\/strong\u003e\u003cbr\u003eThe inclusion of CacheVault flash cache protection and SafeStore ensures critical data is safeguarded against loss or corruption, providing peace of mind and enhanced data security.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eOptimized for demanding environments\u003c\/strong\u003e\u003cbr\u003eDesigned to operate within a wide range of environmental conditions, with operating humidity from 20 - 90% (non-condensing) and temperatures from 0°C to 55°C, ensuring reliable performance in various operational scenarios.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eDevice Type \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Storage controller (RAID) - plug-in card - low profile \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eHost Bus \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e PCIe 3.0 x8 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eStorage Controller\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eInterface \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e SATA \/ SAS 12Gb\/s \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eData Transfer Rate \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 12 Gbit\/s \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eBuffer Size \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 4 GB \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eSupported Devices \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Hard drive, disk array (RAID), solid state drive \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eChannel Qty \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 16 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eMax Storage Devices Qty \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 16 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eRAID Level \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, RAID 50, JBOD, RAID 60 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eProcessor \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e LSI LSISAS3516 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eExpansion \/ Connectivity\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eInterfaces \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 4 x SAS 12Gb\/s - 4 x Mini SAS HD (SFF-8643) (internal) \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eMiscellaneous\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eFeatures \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e CacheVault flash cache protection, FastPath, SafeStore \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eCompliant Standards \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e EN55022, EN55024, ICES-003 Class B, RoHS, WEEE, FCC Part 15 A, VCCI V-3, AS\/NZS CISPR 22, CNS 13438, FCC CFR47 Part 15 B Class B, IEC\/EN\/UL 60950 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eSoftware \/ System Requirements\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eOS Required \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e SuSE Linux Enterprise Server 11 for x86\/AMD64\/Intel EM64T, Red Hat Linux Enterprise Server 6 x64 Edition, Microsoft Windows Server 2012 R2, Red Hat Enterprise Linux 7, SUSE LINUX Enterprise Server 11 with Xen for AMD64\/EM64T, SuSE Linux Enterprise Server 12, VMware vSphere 6.0 (ESXi), SuSE Linux Enterprise Server 12 with Xen, Microsoft Windows Server 2016, VMware vSphere 6.5 (ESXi) \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eManufacturer Warranty\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eService \u0026amp; Support \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Limited warranty - 1 year \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eEnvironmental Parameters\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eMin Operating Temperature \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 0 °C \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eMax Operating Temperature \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 55 °C \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eHumidity Range Operating \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 20 - 90% (non-condensing) \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eCompatibility Information\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eDesigned For \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Lenovo ThinkSystem SR250\u003cbr\u003e Lenovo ThinkSystem SR530 7X07\u003cbr\u003e Lenovo ThinkSystem SR550\u003cbr\u003e Lenovo ThinkSystem SR570\u003cbr\u003e Lenovo ThinkSystem SR590\u003cbr\u003e Lenovo ThinkSystem SR630\u003cbr\u003e Lenovo ThinkSystem SR630 V2 7Z71\u003cbr\u003e Lenovo ThinkSystem SR645 7D2X\u003cbr\u003e Lenovo ThinkSystem SR650\u003cbr\u003e Lenovo ThinkSystem SR650 V2 7D15, 7Z73\u003cbr\u003e Lenovo ThinkSystem SR665 7D2V, 7D2W\u003cbr\u003e Lenovo ThinkSystem SR850\u003cbr\u003e Lenovo ThinkSystem SR850 V2 7D32\u003cbr\u003e Lenovo ThinkSystem SR860\u003cbr\u003e Lenovo ThinkSystem SR860 V2 7Z60\u003cbr\u003e Lenovo ThinkSystem SR950\u003cbr\u003e Lenovo ThinkSystem ST250\u003cbr\u003e Lenovo ThinkSystem ST550\u003cbr\u003e Lenovo ThinkSystem ST650 V2 7Z74, 7Z75 \u003c\/td\u003e \n  \u003c\/tr\u003e \n \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lenovo","offers":[{"title":"Default Title","offer_id":50655000166741,"sku":"KXG0142668","price":1134.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2680\/7864\/files\/Lenovo_7Y37A01085_37583723_a3198889-b64f-4470-864a-48f2f0d42195.jpg?v=1746761878","url":"https:\/\/www.smartx.bg\/en\/products\/lenovo-thinksystem-raid-93016i-4gb-flash-pcie-12gb-adapter","provider":"SmartX.bg","version":"1.0","type":"link"}