{"product_id":"lenovo-emulex-16gb-gen6-fc-hba-s-edin-port","title":"LENOVO Emulex 16Gb Gen6 FC HBA с един порт","description":"\u003cdiv class=\"productName\"\u003e\n LENOVO Emulex 16Gb Gen6 FC Single-port HBA\n\u003c\/div\u003e \n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"head\"\u003e \n \u003ctbody\u003e\n  \u003ctr class=\"alt-0\"\u003e \n   \u003ctd class=\"name\"\u003e \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e \u003c\/td\u003e \n   \u003ctd class=\"image\" rowspan=\"4\"\u003e\u003cimg src=\"https:\/\/actebis-images.com\/productimages\/4acdfc09-d0b3-4363-839a-f2e2c8104f32.jpg\"\u003e\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eManufacturer\u003c\/td\u003e \n   \u003ctd class=\"value\"\u003eLENOVO\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eManufacturer Part No\u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e01CV830\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr\u003e\n   \u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n  \u003c\/tr\u003e \n \u003c\/tbody\u003e\n\u003c\/table\u003e \n\u003ctable cellpadding=\"0\" cellspacing=\"0\" class=\"properties\"\u003e \n \u003ctbody\u003e\n  \u003ctr class=\"sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eMarketing Description\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"marketingText\"\u003e\n   \u003ctd colspan=\"2\"\u003eThe Emulex Fiber Channel (FC) host bus adapter (HBAs) is an ideal solution for servers requiring high-speed data transfer in storage connectivity for virtualized environments, data backup, and mission-critical applications. It is designed to meet the needs of modern networked storage systems that utilize high-performance and low-latency solid-state storage drives for caching and persistent storage as well as hard disk drive arrays. The Emulex FC HBA features ExpressLane, which prioritizes mission-critical traffic in congested networks ensuring maximum application performance on flash storage arrays.\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"sectionHead\"\u003e \n   \u003ctd colspan=\"2\"\u003eProduct Features\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"featuresText\"\u003e \n   \u003ctd colspan=\"2\"\u003e\n    \u003cul\u003e\n     \u003cli\u003e\n\u003cstrong\u003ePlenty of input \/ output operations\u003c\/strong\u003e\u003cbr\u003eMaximum performance with up to 1.6 million input \/ output operations per second (IOPS) to support larger server virtualization deployments and scalable cloud initiatives, and performance to match multicore processors, SSDs \/ flash storage, and faster server host bus architectures.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eExpressLane technology\u003c\/strong\u003e\u003cbr\u003eOffer end-to-end Quality of Service (QoS) application prioritization with ExpressLane technology, which allows customers to prioritize faster storage traffic (such as SSDs) ahead of slower traffic (such as spinning hard drives), alleviating potential bottlenecks from slow storage.\u003c\/li\u003e\n     \u003cli\u003e\n\u003cstrong\u003eIncreased link efficiency\u003c\/strong\u003e\u003cbr\u003eFrame-level multiplexing and out-of-order frame reassembly increases link efficiency and maximizes HBA performance.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eDevice Type \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Host bus adapter \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eForm Factor \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Plug-in card - low profile \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eInterface (Bus) Type \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e PCI Express 3.0 x8 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eNetworking\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003ePorts \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 16Gb Fibre Channel \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eConnectivity Technology \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Wired \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eData Link Protocol \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 4Gb Fibre Channel, 8Gb Fibre Channel, 16Gb Fibre Channel \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eFibre Channel \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e FC-DA, FC-FS, FC-GS-2, FC-GS-3, FC-GS-4, FC-MI, FC-PH, FC-PH-2, FC-PH-3, FC-PI, FC-Tape, FCP-4, FCP-2, FC-PI-2, FC-GS-5, FCP-3, FC-PI-4, FC-FS-3, FC-GS-6, FC-PI-3, FC-HBA, FC-PI-5, FC-LS-2, FC-DA-2, SSC-2, SBC-2, SPC-3, FC-PI-6, SBC-3, SPC-4, SSC-4 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eData Transfer Rate \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 14.025 Gbps \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003ePerformance \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Maximum IOPS: 1600000 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eFeatures \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e QoS, SR-IOV, FEC, MSI-X \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eProcessor \/ Memory\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eProcessor \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 1 x Emulex \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eExpansion \/ Connectivity\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eInterfaces \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 1 x 16Gb Fibre Channel - SFP+ \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eMiscellaneous\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eIncluded Accessories \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Low-profile bracket, full-height bracket, 16 Gb shortwave Fibre Channel SFP+ LC transceiver \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eMTBF \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 10,000,000 hour(s) \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eCompliant Standards \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e ICES-003 Class A, UL 60950-1 Second Edition, CSA C22.2 No. 60950-1-07, FCC Part 15 A, BSMI Class A, VCCI Class A, MSIP Class A, China RoHS, RCM, RoHS 2011\/65\/EU, EN55022:2010 Class A, AS\/NZS CISPR22:2009+A1 Class A, EN 55024:2010, EN 55032:2012, EN60950-1+A11+A1+A12+A2 \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eSoftware \/ System Requirements\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eOS Required \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Microsoft Windows Server 2012, Microsoft Windows Server 2012 R2, SuSE Linux Enterprise Server 12, VMware vSphere 5.5 update 2, SuSE Linux Enterprise Server 12 SP1, SuSE Linux Enterprise Server 11 SP4 for AMD64\/EM64T, SuSE Linux Enterprise Server 11 SP3 for AMD64\/EM64T, VMware vSphere 5.5 update 3, VMware vSphere 6.0 update 1, VMware vSphere 6.0 update 2, Red Hat Enterprise Linux 7 Update 2, Red Hat Enterprise Linux 7 Update 1, Red Hat Linux Enterprise Server 6 Update 7 x64 Edition \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eDepth \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 16.8 cm \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eHeight \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 6.9 cm \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eManufacturer Warranty\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eService \u0026amp; Support \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Limited warranty - 1 year \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eEnvironmental Parameters\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eMin Operating Temperature \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 0 °C \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-1\"\u003e \n   \u003ctd class=\"name\"\u003eMax Operating Temperature \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 55 °C \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eHumidity Range Operating \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e 5 - 95% (non-condensing) \u003c\/td\u003e \n  \u003c\/tr\u003e \n  \u003ctr class=\"espec sectionHead\"\u003e\n   \u003ctd colspan=\"2\"\u003eCompatibility Information\u003c\/td\u003e\n  \u003c\/tr\u003e \n  \u003ctr class=\"espec alt-0\"\u003e \n   \u003ctd class=\"name\"\u003eDesigned For \u003c\/td\u003e \n   \u003ctd class=\"value\"\u003e Lenovo NeXtScale nx360 M5 5465\u003cbr\u003e Lenovo System x3500 M5 5464\u003cbr\u003e Lenovo System x3550 M5 5463, 8869\u003cbr\u003e Lenovo System x3650 M5 5462, 8871\u003cbr\u003e Lenovo System x3750 M4 8753\u003cbr\u003e Lenovo System x3850 X6 6241\u003cbr\u003e Lenovo System x3950 X6 6241\u003cbr\u003e Lenovo ThinkSystem SR250\u003cbr\u003e Lenovo ThinkSystem SR530 7X08\u003cbr\u003e Lenovo ThinkSystem SR590\u003cbr\u003e Lenovo ThinkSystem SR630 7X02\u003cbr\u003e Lenovo ThinkSystem SR630 V2 7Z71\u003cbr\u003e Lenovo ThinkSystem SR645 7D2X\u003cbr\u003e Lenovo ThinkSystem SR650 7X06\u003cbr\u003e Lenovo ThinkSystem SR650 V2 7D15, 7Z73\u003cbr\u003e Lenovo ThinkSystem SR665 7D2V, 7D2W\u003cbr\u003e Lenovo ThinkSystem SR850 V2 7D32\u003cbr\u003e Lenovo ThinkSystem ST250\u003cbr\u003e Lenovo ThinkSystem ST550 7X10\u003cbr\u003e Lenovo ThinkSystem ST650 V2 7Z74, 7Z75 \u003c\/td\u003e \n  \u003c\/tr\u003e \n \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lenovo","offers":[{"title":"Default Title","offer_id":50654158946645,"sku":"KXG0138450","price":811.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2680\/7864\/files\/Lenovo_01CV830_89348225_ec48f179-a098-46da-819c-20566ac57d86.jpg?v=1746752603","url":"https:\/\/www.smartx.bg\/products\/lenovo-emulex-16gb-gen6-fc-hba-s-edin-port","provider":"SmartX.bg","version":"1.0","type":"link"}